This is Jay , clinical specialist from ShangHai SDC. Glad to see you

My comments and questions are as blow (green part, and these experience base on Chinese market)

â‘ Work spaces either not setup, or incorrectly set up
(Most Default work space setting should be match their anatomy, Ex: CHEST PA —-Default work space should be Wall stand , and FOOT AP —Default work space should be table )

â‘¡No erect or supine views anymore – but Ascend requires a work space ot be mapped for Every view – unlike an Evo ‘
(In China , we would like to select Chest PA rather than select Chest-PA-Erect or Chest-PA-Suspine ,if radiologists decide to perform exposure for Chest PA on table as their patient is not able to stand themselves, they will change workspace and to select Table work space 。 Or they will choose Chest AP (default workspace is table) to perform exposure
Do you agree with my comments?

â‘¢LLI Views in the shipped views dont work, the real views have been uncategorised
(I also found out that there are not any LLI Views in default WW-ascend APR indeed ,the real views have been uncategorised )

@ Jennifer, I heard from Shino that there might be an upgrade of APR for LLI category for WW-Acend。There is an APR( for xinshang), including LLI views , I attached it in this mail
Could you please check it in your test room? I think the LLI views in this APR should be right

â‘£AEC back up timer is 600mA for every view – and every work space. If on fine focus. the timer is too long

There are two questions here
Firstly :I think AEC back up should be MAS value (ex:600 mAs)

Second,
“on fine focus†, does it mean small focus ?if yes , I think ALL MA setting of small focus are nearly between 100MA and 200MA
( AEC back up= 600MAS )leads to make actual detector’s integration time would over 3.2xx seconds , so exposure would be blocked
@ Jennifer if we adjust the value of most AEC back up (small focus) to 300 MAS , do you think that it makes sense ?


This is Jay, clinical specialist from ShangHai SDC. Glad to meet you

My comments and questions are as below (in green, and between brackets( ) , based on my experience of the Chinese market)

â‘ Work spaces either not setup, or incorrectly set up
(Most Default work space setting should be match human anatomy, Ex: CHEST PA —-Default work space should be Wall stand , and FOOT AP —Default work space should be table )

â‘¡No erect or supine views anymore – but Ascend requires a work space to be mapped for Every view – unlike an Evo ‘
(In China , we would like to select Chest PA rather than select Chest-PA-Erect or Chest-PA-Suspine ,if radiologists decide to perform exposure for Chest PA on table if their patients are not able to stand by themselves, they will change workspace and to select a Table work space 。 Or they will choose Chest AP (default workspace is table) to perform exposure
Do you agree with my comments?

â‘¢LLI Views in the shipped views dont work, the real views have been uncategorised
(I also found out that there are not any LLI Views in the default WW-ascend APR. The real views have indeed been uncategorised )

@ Jennifer, I heard from Shino that there might be an upgrade of APR for LLI category for WW-Acend。There is an APR( for xinshang), including LLI views , I attached it in this mail
Could you please check it in your test room? I think the LLI views in this APR should be right

â‘£The AEC backup timer is 600mA for every view – and every work space. If it is for  fine focus. the timer is too long

There are two questions here
Firstly :I think AEC backup should be MAS value (ex:600 mAs)

Second,
“on fine focus†, does it mean small focus ?if yes , I think ALL MA setting of small focus are nearly between 100MA and 200MA
( AEC back up= 600MAS ), which leads to making actual detector’s integration time would over 3.2xx seconds , so exposure would be blocked
@ Jennifer if we adjust the value of most AEC back up (small focus) to 300 MAS , do you think that it makes sense ?